• R160 Woltman Water Meter
  • R160 Woltman Water Meter
  • R160 Woltman Water Meter

R160 Woltman Water Meter

After-sales Service: 2 Years
Warranty: 2 Years
Install: Horizontal
Medium Temperature: Cold Water
Level Measurement: C
Counter Instructions: Digital
Samples:
US$ 1/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
LXLC-**E4
Nominal Diameter
Big Diameter
Application
Civil, Industrial
Principle
Speed of Water Meter
Medium Pressure
General Water Meter
Work Environment
Dry Water Meter
Stucture
Traditional
Specification
DN50 ~ DN200
Trademark
younio
Origin
China
HS Code
9028201000
Production Capacity
140000/Month

Product Description

PR160 Woltman Water Meterroduct Description

1. Features of R160 Woltman Water Meter with Inductive Pre-equipped

Hermetically sealed register(IP 68)

Hydrodynamically balanced system

Register may be rotated through 360

High overload capability

Pattern approved removable measuring element

Powder coating affords max. corrosion protection

Not affected by external magnetic fields

Available for cold water 0~30ºC and hot water30ºC~90ºC

2. Working condition of R160 Woltman Water Meter with Inductive Pre-equipped

Water temperature≤30ºC; hot water meter ≤90ºC.

Water pressure≤1MPa (PN:1.6MPa/16bar)

ΔP≤0.63MPa

3. Accuracy of R160 Woltman Water Meter with Inductive Pre-equipped

From minimum flow-rate(qmin) inclusive , to transitional flow- rate(qt) exclusive:±5%

From transitional flow- rate(qt) inclusive , to overload flow- rate(qs) exclusive:±2%

4. Upon request of R160 Woltman Water Meter with Inductive Pre-equipped

Remote transmission device can be added upon request

Pulse output 100L/Pulse ,1000 L/Pulse

5. Head Loss Curve of R160 Woltman Water Meter with Inductive Pre-equipped

 

6. Error Curve of R160 Woltman Water Meter with Inductive Pre-equipped

 

7. Dimension of R160 Woltman Water Meter with Inductive Pre-equipped

Product Description

1. Features of R160 Woltman Water Meter with Inductive Pre-equipped

Hermetically sealed register(IP 68)

Hydrodynamically balanced system

Register may be rotated through 360

High overload capability

Pattern approved removable measuring element

Powder coating affords max. corrosion protection

Not affected by external magnetic fields

Available for cold water 0~30ºC and hot water30ºC~90ºC

2. Working condition of R160 Woltman Water Meter with Inductive Pre-equipped

Water temperature≤30ºC; hot water meter ≤90ºC.

Water pressure≤1MPa (PN:1.6MPa/16bar)

ΔP≤0.63MPa

3. Accuracy of R160 Woltman Water Meter with Inductive Pre-equipped

From minimum flow-rate(qmin) inclusive , to transitional flow- rate(qt) exclusive:±5%

From transitional flow- rate(qt) inclusive , to overload flow- rate(qs) exclusive:±2%

4. Upon request of R160 Woltman Water Meter with Inductive Pre-equipped

Remote transmission device can be added upon request

Pulse output 100L/Pulse ,1000 L/Pulse

5. Head Loss Curve of R160 Woltman Water Meter with Inductive Pre-equipped

 

6. Error Curve of R160 Woltman Water Meter with Inductive Pre-equipped

 

7. Dimension of R160 Woltman Water Meter with Inductive Pre-equipped

 

Model Number LXLC-50E4a/RLN1 LXLC-65E4a/RLN1 LXLC-80E4a/RLN1 LXLC-100E4a/RLN1 LXLC-125E4a/RLN1 LXLC-150E4a/RLN1 LXLC-200E4a/RLN1
L mm 200 200 225 250 250 300 350
H mm 200 208 245 245 275 350 370
W mm 165 185 200 200 220 285 347
D mm 160 180 195 215 245 285 340
D1 mm 125 145 160 180 210 240 295
Connecting bolt(pcs.) 4×M16 4XM16 8×M16 8×M16 8xM16 8×M20 12×M20
Weight 8.00 9.50 14.50 16.80 20.00 36.00 44.50

8. Main technical data of R160 Woltman Water Meter with Inductive Pre-equipped

Model Number LXLC-50E4a/RLN1 LXLC-65E4a/RLN1 LXLC-80E4a/RLN1 LXLC-100E4a/RLN1 LXLC-125E4a/RLN1 LXLC-150E4a/RLN1 LXLC-200E4a/RLN1
Nominal diameter (DN)[mm]: 50 65 80 100 125 150 200
Ratio Q3/Q1: R100 R160 R100 R160 R100 R160 R100 R160 R100 R160 R100 R160 R100 R160
Overload flow rate (Q4) [m³/h] 50 78.75 78.75 78.75 125 125 200 200 200 312.5 500 500 787.5 787.5
Permanent flow rate (Q3) [m³/h] 40 40 63 63 100 100 160 160 250 250 400 400 630 630
Transitional flow rate (Q2) [m³/h] 0.64 0.63 1.008 0.63 1.6 1 2.56 1.6 2.56 2.5 6.4 4 10.08 6.3
Minimum flow rate (Q1) [m³/h] 0.4 0.394 0.63 0.394 1 0.625 1.6 1 1.6 1.5625 4 2.5 6.3 3.9375
Accuracy class: 2
Maximum permissible error for the
lower flow rate zone (MPEι):
±5%
Maximum permissible error for
the upper flow rate zone (MPEμ):
±2% for water having a temperature ≤30ºC
±3% for water having a temperature >30ºC
Temperature class: T30 and T50
Water pressure classes: MAP 16
Pressure-loss classes: △P40
Indicating range[m3]: 999999
Resolution of the
indicating device[m3]:
0.0005
Flow profile sensitivity classes: U10 D5
Orientation limitation: YES
Connection Thread: Flange connecting

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
162
Year of Establishment
2011-09-27