Dn65 Wp-Dynamic Turbine Water Meter

Product Details
Customization: Available
Install: Horizontal
Medium Temperature: Cold Water
Still deciding? Get samples of US$ 100/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
162
Year of Establishment
2011-09-27
  • Dn65 Wp-Dynamic Turbine Water Meter
  • Dn65 Wp-Dynamic Turbine Water Meter
  • Dn65 Wp-Dynamic Turbine Water Meter
  • Dn65 Wp-Dynamic Turbine Water Meter
  • Dn65 Wp-Dynamic Turbine Water Meter
  • Dn65 Wp-Dynamic Turbine Water Meter
Find Similar Products

Basic Info.

Model NO.
LXLC-65E/W
Counter Instructions
Digital
Nominal Diameter
50-100mm
Application
Civil, Industrial
Principle
Speed of Water Meter
Medium Pressure
General Water Meter
Work Environment
Dry Water Meter
Size
Dn50-Dn200
Body Material
Ductil Iron Body
Transport Package
Carton/ Pallets
Specification
ISO4064
Trademark
younio or OEM
Origin
Zhejiang, China
HS Code
9028201000
Production Capacity
1000/Month

Product Description


Feature:

  • Hermetically sealed register(IP 68)
  • Hydrodynamically balanced system
  • Register may be rotated through 360
  • High overload capability
  • Pattern approved removable measuring element
  • Poweder coating affords max.corrosion protection
  • Not affected by external magnetic fields
  • Available for cold water 0~30ºC and hot water30ºC~90ºC

Dimension:

Dn65 Wp-Dynamic Turbine Water Meter

Technical Data:

Nominal diameter (DN)[mm]: 50 65 80 100 125 150 200
Ratio Q3/Q1: ≤200for H installations
Ratio Q2/Q1: 1.6
Ratio Q4/Q3: 1.25
Accuracy class: 2

Maximum permissible error

 for the lower flowrate zone (MPEι):

±5%

Maximum permissible error 

for the upper flowrate zone (MPEμ):

±2% for water temperature≤30ºC
±3% for water temperature>30ºC
Temperature class: T30 and T50
Water pressure classes: MAP 16
Pressure-loss classes: P40 P40 P40 P40 P40 P40 P40
Indicating range[m3]: 999999 9999999

Resolution of the

 indicating device[m3]:

0.0005 0.005
Flow profile sensitivity classes: U10 D5
Orientation limitation: YES
Length L[mm]: 200 200 225 250 250 300 350
Connection type-Screw thread size: Flange connection

 

Nominal 

diameter (DN):

Installation 

position:

Ratio 

Q3/Q1:

Minimum 

flowrate(Q1)

Transitional 

flowrate(Q2)

Permanent 

flowrate(Q3)

Overload 

flowrate(Q4)

mm - - M3/h M3/h M3/h M3/h
50 H R80 0.5 0.8 40 50
R100 0.4 0.64 40 50
R160 0.394 0.63 63 78.75
R200 0.32 0.51 63 78.75
65 H R80 0.7875 1.26 63 78.75
R100 0.63 1.008 63 78.75
R160 0.394 0.63 63 78.75
R200 0.32 0.51 63 78.75
80 H R80 0.7875 1.26 63 78.75
R100 1 1.6 100 125
R160 0.625 1 100 125
R200 0.5 0.8 100 125
100 H R80 1.25 2 100 125
R100 1.6 2.56 160 200
R160 1 1.6 160 200
R200 0.8 1.28 160 200
125 H R80 2 3.2 160 200
R100 1.6 2.56 160 200
R160 1.5625 2.5 250 312.5
R200 1.25 2 250 312.5
150 H R80 3.125 5 250 312.5
R100 4 6.4 400 500
R160 2.5 4 400 500
R200 2 3.2 400 500
200 H R80 5 8 400 500
R100 6.3 10.08 630 787.5
R160 3.9375 6.3 630 787.5
R200 3.15 5 630 787.5

 