Customization: | Available |
---|---|
Install: | Horizontal |
Medium Temperature: | Cold Water |
Still deciding? Get samples of US$ 18/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Technical Features | |||||||||||||||
Model Number | LXSY-15E/B | LXSY-20E/B | LXSY-25E/B | LXSY-40E/B | LXSY-50E/B | ||||||||||
Nominal diameter (DN)[mm]: | 15 | 20 | 25 | 40 | 50 | ||||||||||
Ratio Q3/Q1: | R80 | R100 | 160 | R80 | R100 | 160 | R80 | R100 | 160 | R80 | R100 | 160 | R80 | R100 | 160 |
Overload flow rate (Q4) [m³/h] | 3.125 | 3.125 | 3.125 | 5 | 5 | 5 | 7.875 | 7.875 | 7.875 | 20 | 20 | 20 | 31.25 | 31.25 | 31.25 |
Permanent flow rate (Q3) [m³/h] | 2.5 | 2.5 | 2.5 | 4 | 4 | 4 | 6.3 | 6.3 | 6.3 | 16 | 16 | 16 | 25 | 25 | 25 |
Transitional flow rate (Q2) [m³/h] | 0.05 | 0.04 | 0.025 | 0.08 | 0.064 | 0.04 | 0.126 | 0.1008 | 0.063 | 0.32 | 0.256 | 0.16 | 0.4 | 0.4 | 0.25 |
Minimum flow rate (Q1) [m³/h] | 0.03125 | 0.025 | 0.01563 | 0.05 | 0.04 | 0.025 | 0.07875 | 0.063 | 0.03938 | 0.2 | 0.16 | 0.1 | 0.25 | 0.25 | 0.15625 |
Ratio Q2/Q1: | 1.6 | ||||||||||||||
Ratio Q4/Q3: | 1.25 | ||||||||||||||
Accuracy class: | 2 | ||||||||||||||
Maximum permissible error for the lower flow rate zone (MPEι): | ±5% | ||||||||||||||
Maximum permissible error for the upper flow rate zone (MPEμ): | ±2% water temperature≤30ºC | ||||||||||||||
Temperature class: | T30 | ||||||||||||||
Water pressure classes: | MAP 16 | ||||||||||||||
Pressure-loss classes: | △P63 | ||||||||||||||
Indicating range[m3]: | 99 999 | ||||||||||||||
Resolution of the indicating device[m3]: | 0.00005 | ||||||||||||||
Flow profile sensitivity classes: | U0 D0 | ||||||||||||||
Orientation limitation: | H | ||||||||||||||
Length L[mm]: | 165 | 190 | 260 | 300 | 300 | ||||||||||
Connection type-Screw thread size: | G3/4B | G1B | G 1 1/4B | G2B | G2B |